GECINA - REFERENCE DOCUMENT 2017
FROM CORPORATE RESPONSIBILITY TO SUSTAINABLE PERFORMANCE Priority 3: reduce environmental footprint by a resource-efficient and carbon-neutral real estate
ENERGY PERFORMANCE OF THE COMMERCIAL PROPERTY PORTFOLIO IN OPERATION BASED ON THE RECOMMENDATIONS OF FRANCE GBC (ALL USES)
Activities (operation controlled by Gecina excluding specific tenant uses)
Stakeholders (operation controlled by tenants and specific tenant uses)
Corporate (head office)
Property portfolio
Total
kWhPE
3,889,635 3,766,078
160,703,310 153,099,860
271,274,019 435,866,964 283,988,039 440,853,977
kWhPE climate adjusted*
Heating/cooling DDU adjusted for property portfolio (see reporting protocol on the Gecina website * http://www.gecina.fr/en/csr/reporting-ecosystem.html).
ENERGY PERFORMANCE OF THE PROPERTY PORTFOLIO UNDER DEVELOPMENT (EXCLUDING SPECIFIC TENANT USES)
Annual energy performance before rebuilding
Annual energy performance after rebuilding
Projects whose design has been finalized
Le France 7 Madrid
237 kWhFE/sq.m 237 kWhFE/sq.m 131 kWhFE/sq.m 192 kWhFE/sq.m 188 kWhFE/sq.m
87 kWhFE/sq.m 61 kWhFE/sq.m 68 kWhFE/sq.m 69 kWhFE/sq.m 63 kWhFE/sq.m 70 kWhFE/sq.m 52 kWhFE/sq.m 69 kWhFE/sq.m
Octant Sextant
32 Guersant
20 Ville-l’Évêque
Sky 56 Be Issy
na na
Ibox
234 kWhFE/sq.m
: not applicable na
As stated in Chapter 7.5.1.3, the table above only shows the performance of projects whose design has been finalized. Of these developments, only one does not meet the target of 70 kWhFE/sq.m/year, given the nature of the work done. It is not as significant as that taken into account to set the overall goal for the performance of reconstruction projects.
Energy performance of the office properties in operation 7.5.2.3.2
Reminder of the 2020 targets: Offices without usage: 284 kWhEP/sq.m/year, i.e. ■ -40% compared with 2008
Office ■ 430 kWhPE/sq.m/year, i.e. -35% compared with 2008 portfolio including all uses:
CHANGE IN OFFICE PORTFOLIO ENERGY CONSUMPTION R
Change since 2008
Change 2016/2017
07
2008
2016
2017
kWhPE heating climate adjusted* kWhPE/sq.m/year climate adjusted* kWhPE climate adjusted* per occupant kWhPE heating climate adjusted* kWhPE/sq.m/year climate adjusted* kWhPE climate adjusted* per occupant
315,698,545 228,758,744 207,498,455
-
Excluding specific uses
473
307
291
-38% -5%
-
5,231
5,019
-
-4%
450,900,370 354,094,813 329,865,332
Including specific uses
475
463
-30% -2%
659
-11%
-
8,097
7,237
-
* Heating/cooling DDU adjusted for property portfolio (see reporting protocol on the Gecina website http://www.gecina.fr/en/csr/reporting-ecosystem.html).