GECINA - REFERENCE DOCUMENT 2017

FROM CORPORATE RESPONSIBILITY TO SUSTAINABLE PERFORMANCE Priority 3: reduce environmental footprint by a resource-efficient and carbon-neutral real estate

ENERGY PERFORMANCE OF THE COMMERCIAL PROPERTY PORTFOLIO IN OPERATION BASED ON THE RECOMMENDATIONS OF FRANCE GBC (ALL USES)

Activities (operation controlled by Gecina excluding specific tenant uses)

Stakeholders (operation controlled by tenants and specific tenant uses)

Corporate (head office)

Property portfolio

Total

kWhPE

3,889,635 3,766,078

160,703,310 153,099,860

271,274,019 435,866,964 283,988,039 440,853,977

kWhPE climate adjusted*

Heating/cooling DDU adjusted for property portfolio (see reporting protocol on the Gecina website * http://www.gecina.fr/en/csr/reporting-ecosystem.html).

ENERGY PERFORMANCE OF THE PROPERTY PORTFOLIO UNDER DEVELOPMENT (EXCLUDING SPECIFIC TENANT USES)

Annual energy performance before rebuilding

Annual energy performance after rebuilding

Projects whose design has been finalized

Le France 7 Madrid

237 kWhFE/sq.m 237 kWhFE/sq.m 131 kWhFE/sq.m 192 kWhFE/sq.m 188 kWhFE/sq.m

87 kWhFE/sq.m 61 kWhFE/sq.m 68 kWhFE/sq.m 69 kWhFE/sq.m 63 kWhFE/sq.m 70 kWhFE/sq.m 52 kWhFE/sq.m 69 kWhFE/sq.m

Octant Sextant

32 Guersant

20 Ville-l’Évêque

Sky 56 Be Issy

na na

Ibox

234 kWhFE/sq.m

: not applicable na

As stated in Chapter 7.5.1.3, the table above only shows the performance of projects whose design has been finalized. Of these developments, only one does not meet the target of 70 kWhFE/sq.m/year, given the nature of the work done. It is not as significant as that taken into account to set the overall goal for the performance of reconstruction projects.

Energy performance of the office properties in operation 7.5.2.3.2

Reminder of the 2020 targets: Offices without usage: 284 kWhEP/sq.m/year, i.e. ■ -40% compared with 2008

Office ■ 430 kWhPE/sq.m/year, i.e. -35% compared with 2008 portfolio including all uses:

CHANGE IN OFFICE PORTFOLIO ENERGY CONSUMPTION R

Change since 2008

Change 2016/2017

07

2008

2016

2017

kWhPE heating climate adjusted* kWhPE/sq.m/year climate adjusted* kWhPE climate adjusted* per occupant kWhPE heating climate adjusted* kWhPE/sq.m/year climate adjusted* kWhPE climate adjusted* per occupant

315,698,545 228,758,744 207,498,455

-

Excluding specific uses

473

307

291

-38% -5%

-

5,231

5,019

-

-4%

450,900,370 354,094,813 329,865,332

Including specific uses

475

463

-30% -2%

659

-11%

-

8,097

7,237

-

* Heating/cooling DDU adjusted for property portfolio (see reporting protocol on the Gecina website http://www.gecina.fr/en/csr/reporting-ecosystem.html).

247

GECINA - REFERENCE DOCUMENT 2017

Made with FlippingBook Online newsletter